Home / concrete flooring on upper levels

concrete flooring on upper levels

Hydronic radiant in slab heating upper floor

In a Ranch-style home with a basement approx 1600 sq ft on each level , can in-floor hydronic radiant loops provide adequate heating to the upper floor also during prolonged winter temps? We live in Omaha, NE. Floor coverings on the slab would be either be carpet or just finished concrete. Plesae assume the house will be well-insulated and air sealed, with "good" windows.

UPPER FLOORS

UPPER FLOORS. Concrete is the ideal construction medium for upper flooring. Its density and strength ensures your floors won't creak or vibrate and helps minimise the transmission of noise between floors. Thermal mass helps keep your home comfortable all year round.

Sound Tranmission and Flooring Types

Hello, I am working on a 30 -story condo building where the customer wants a final polished concrete floor no wood laminate or carpet simply a polished concrete floor. After leveling the floor can I put some sort of sound barrier in between the level floor and the layer of polished concrete?

The Perils of Moisture for Concrete Flooring

Similar mitigation methods can be deployed on the opposite side of concrete flooring slabs in the form of a dispersive membrane or surface-applied moisture vapour barrier. Dispersive membranes are placed on the top of the concrete slab, effectively serving as a barrier between ascending moisture and the upper floor surface.

Creating Nice Concrete Floors

So, to get a smooth freshly poured concrete floor in place will cost about $2.00/sq-ft plus the cost of the material and the cost of the pump truck. All in, a 1000 sq-ft lower level floor with a 5inch slab will cost about $5000. That same area with a 3 inch slab say on an upper level will cost about $4000. Both scenarios include $1000 for

What is the average thickness of the floor/ceiling between

The average 2nd floor use is a 2x12 depending on the span of the room plus the 3/4 in. decking. is the ceiling below over a garage? if so the drywall should be 2 layers thick for firewall codes. the 2x12s are now from 11 1/4 to 11 1/2 wide plus the 3/4 decking plus two thicknesses of 5/8 drywall if needed.

5 Myths about Concrete Moisture Wagner Meters

The target of RH testing is to be able to determine the moisture levels of a concrete slab once the floor covering is applied. Why? Because if the moisture level is too high, it puts the entire floor system at risk, and billions of dollars are spent in repairing moisture-related flooring failures each year.

Upper-Level Concrete Floors

DuWayne Gough Concrete Specialities poured the upper-level concrete floors last week. We specified a 3 inch slab of tinted concrete the same 2% tint we used on the lower-level slab . A 24-inch grid of 2 re-bar is laid over the hydronic heating tubes before the floors are poured.

THE ACOUSTICS OF FLOORS IN CONDOMINIUMS

the levels in the source and receiver room, adjusted for the itself for a minimum quality floor. Six-inch concrete slabs with a wire-hung drywall ceiling and fiberglass insulating floorceiling system does not guarantee that footfall noise. Acoustics of Floors in Condominiums.

Lightweight concrete floors on upper levels

I am exploring concrete floors on the main level over basement to get some mass into the space. They would be stained and sealed to create the finished floor. I am researching the use of ICF style forms that would allow a free span from wall to wall and eliminate the wood floor structure all together. An example is Lite-Deck, which costs around $3.25/sqft of floor surface for the form.

Pros and Cons of Concrete Floors

Plain concrete slabs have served as the flooring material for basements, garages, patios, and utility areas for many years, but concrete is now also a viable material in modern homes, where it can be found in polished, etched, or stained form on the floors of any room in the house.

Acceptable Concrete Moisture

Acceptable Concrete Moisture - July 2013 Pounds? that questions why the flooring industry ever abided by what it calls a one size fits all standard for evaluating concrete slab

Ground and Upper Floors Flooring Concrete Longley Group

Beam and Block for Upper Floors. Infill blocks to be standard solid light aggregate/concrete 440 x 215 x 100mm. Minimum compressive strength of 3.5 N/mm-2 or 7.0 N/mm-2 with a traverse load capacity of 3.5 kN on a 420mm span. When the floor separates a dwelling from another dwelling, it has to comply with Building Regulations Approved Document E.

FLOOR CONSTRUCTION Concrete or Timber Floor?

you intend for that floor area and the floor finish. In recent years the use of suspended concrete floors has become common place normally in the commercial sector, but to a lesser degree, even in upper floors of domestic dwellings. So we will discuss Concrete or Timber floor systems. Type 1: Suspended Floors

How Thick Is the Floor Between Two Levels? Home Guides

The floor of one level of a home shares framing with the ceiling of the level below it. In a typical home, the entire structure between levels can be about 12 to 14 inches thick, depending on the

Waterproof Flooring and Coatings Industrial Epoxy Concrete

A broken water pipe, a backed-up toilet or even a spilled mop bucket can all saturate a floor and send liquids seeping through to the level below. Whether or not upper level floors are exposed to liquids during the course of daily operations, the right waterproof epoxy flooring and coatings can prevent accidents from becoming disasters.

Specifying upper-storey floor structures

With the scaffold at first floor level, the floor joists and any supporting beams can be built into the exterior walls. RSJs reinforced steel joists are often necessary to support an upper floor, especially if the ground floor is largely open plan with few interior supporting walls. Although it is possible to install RSJs and

Reinforced Concrete Slab Level Change Detail

Reinforced Concrete Slab Level Change Detail.CAD ding featuring a change of level between two adjucent slabs supported on a common concrete beam. This CAD detailed ding is a typical reinforced concrete slab detail featuring a change of level between two adjucent slabs supported on a common concrete beam. Includes upper and lower level

Why Measure pH and RH levels in Concrete before Installing

Flooring contractors who work with concrete floor slabs may need to take both pH potential hydrogen and RH relative humidity levels of concrete into serious consideration before attempting to install any flooring materials or risk costly project failures.

Litecast Upper Floor Installation

Installation of our beam and block flooring at upper floor level. Should you require any further information, please visit www.litecast.co.uk or call us on 02476 356 161. Music from bensound.com

Upper floors

Upper floors can be constructed from a concrete beam and block system as discussed earlier in this paper for suspended ground floors but these are only used on flats where high levels of fire resistance and sound protection are required.

Copyright © 2011-.Shanghai Seven Trust Industry Co.,Ltd All Rights Reserved.